This paper presents a novel dual-band substrate integrated waveguide (SIW) sensor that is designed to measure the complex permittivities of liquids or solid powders at two industrial, scientific, and medical (ISM) frequencies simultaneously. Resonant frequencies and quality factors are obtained from S-parameter measurements with the proposed SIW sensor, and applied to reconstructing the permittivities of materials under test through an artificial neural network. The water–ethanol mixed liquids were measured with the proposed sensor. The maximum deviations of the measured permittivities at 2.45 and 5.8 GHz are within 3% of literature results. The measurement by the proposed SIW sensor with artificial neural network reconstruction is accurate and efficient.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: