Key result
A new submaximal rowing test accurately predicted 2,000-m rowing ergometer time, with power during the final stage showing a strong correlation (r = -0.93; 95% CI -0.97 to -0.84).
Why the study?
Does a submaximal rowing test accurately predict 2,000-m rowing ergometer performance in competitive male rowers?
Observational (n=24)
Does a submaximal rowing test accurately predict 2,000-m rowing ergometer performance in competitive male rowers?
The submaximal rowing test is a reliable and practical tool that accurately predicts 2,000-m rowing ergometer performance, aiding in training prescription for competitive rowers.
Should not yet change rowing testing protocols; leaves open prospective validation in competitive athletes.
The purpose of this study was to assess predictive value of a new submaximal rowing test (SmRT) on 2,000-m ergometer rowing time-trial performance in competitive rowers. In addition, the reliability of the SmRT was investigated. Twenty-four competitive male rowers participated in this study. After determining individual HRmax, all rowers performed an SmRT followed by a 2,000-m rowing ergometer time trial. In addition, the SmRT was performed 4 times (2 days in between) to determine the reliability. The SmRT consists of two 6-minute stages of rowing at 70 and 80% HRmax, followed by a 3-minute stage at 90% HRmax. Power was captured during the 3 stages, and 60 seconds of heart rate recovery (HRR60s) was measured directly after the third stage. Results showed that predictive value of power during the SmRT on 2,000-m rowing time also increased with stages. CVTEE% is 2.4, 1.9, and 1.3%. Pearson correlations (95% confidence interval [95% CI]) were -0.73 (-0.88 to -0.45), -0.80 (-0.94 to -0.67), and -0.93 (-0.97 to -0.84). 2,000-m rowing time and HRR60s showed no relationship. Reliability of power during the SmRT improved with the increasing intensity of the stages. The coefficient of variation (CVTEM%) was 9.2, 5.6, and 0.4%. Intraclass correlation coefficients (ICC) and 95% CI were 0.91 (0.78-0.97), 0.92 (0.81-0.97), and 0.99 (0.97-1.00). The CVTEM% and ICC of HRR60s were 8.1% and 0.93 (0.82-0.98). In conclusion, the data of this study shows that the SmRT is a reliable test that it is able to accurately predict 2,000-m rowing time on an ergometer. The SmRT is a practical and valuable submaximal test for rowers, which can potentially assist with monitoring, fine-tuning and optimizing training prescription in rowers.
No takes yet. Share an insight, caveat, or question.
Otter et al. (2015) conducted an observational in Competitive rowers (n=24). Submaximal rowing test (SmRT) was evaluated on Predictive value of power during the SmRT on 2,000-m rowing time (Pearson correlation -0.93, 95% CI -0.97 to -0.84). A new submaximal rowing test accurately predicted 2,000-m rowing ergometer time, with power during the final stage showing a strong correlation (r = -0.93; 95% CI -0.97 to -0.84).