Key result
Non-invasive fetal electrocardiography combined with artificial intelligence detected congenital heart disease with an overall accuracy of 71%, sensitivity of 63%, and specificity of 77%.
Why the study?
This study was conducted to investigate non-invasive fetal electrocardiography combined with artificial intelligence as a method for prenatal detection of congenital heart disease.
Does an artificial neural network analyzing non-invasive fetal electrocardiography accurately detect congenital heart disease?
Observational (n=122)
Does an artificial neural network analyzing non-invasive fetal electrocardiography accurately detect congenital heart disease?
AI-assisted analysis of non-invasive fetal electrocardiography demonstrates feasibility as a complementary screening tool for prenatal detection of congenital heart disease.
Answers are grounded in this paper and cite their sources.
May complement fetal CHD screening; hypothesis-generating and requires prospective validation before clinical adoption.
INTRODUCTION: This study aims to investigate non-invasive electrocardiography as a method for the detection of congenital heart disease (CHD) with the help of artificial intelligence. MATERIAL AND METHODS: An artificial neural network was trained for the identification of CHD using non-invasively obtained fetal electrocardiograms. With the help of a Bayesian updating rule, multiple electrocardiographs were used to increase the algorithm's performance. RESULTS: Using 122 measurements containing 65 healthy and 57 CHD cases, the accuracy, sensitivity, and specificity were found to be 71%, 63%, and 77%, respectively. The sensitivity was however 75% and 69% for CHD cases requiring an intervention in the neonatal period and first year of life, respectively. Furthermore, a positive effect of measurement length on the detection performance was observed, reaching optimal performance when using 14 electrocardiography segments (37.5 min) or more. A small negative trend between gestational age and accuracy was found. CONCLUSIONS: The proposed method combining recent advances in obtaining non-invasive fetal electrocardiography with artificial intelligence for the automatic detection of CHD achieved a detection rate of 63% for all CHD and 75% for critical CHD. This feasibility study shows that detection rates of CHD might improve by using electrocardiography-based screening complementary to the standard ultrasound-based screening. More research is required to improve performance and determine the benefits to clinical practice.
No takes yet. Share an insight, caveat, or question.
Vries et al. (2023) conducted an observational in Congenital heart disease (CHD) (n=122). Non-invasive fetal electrocardiography with artificial intelligence was evaluated on Detection of congenital heart disease (accuracy, sensitivity, and specificity). Non-invasive fetal electrocardiography combined with artificial intelligence detected congenital heart disease with an overall accuracy of 71%, sensitivity of 63%, and specificity of 77%.
Synapse has enriched 10 related papers. Consider them for comparative context: