In order to measure platelet-associated IgG (PAIgG), we devised a solid-phase enzyme immunoassay employing a competitive binding of peroxidase-conjugated anti-IgG antiserum between platelets and polystyrene tubes coated with IgG. The amounts of peroxidase bound to the tubes were measured in a spectrophotometer by an enzymatic reaction. This method is highly sensitive, reproducible and can be carried out more simply. the PAIgG values of normal controls averaged 21.6 +/- 6.6 (SD) ng/10(7) platelets. 27 (93%) of 29 patients with idiopathic thrombocytopenic purpura (ITP), who had a platelet count of less than 15 X 10(4)/microliter, had PAIgG values greater than those of controls by 2 SD and averaged 205.5 +/- 323 ng. There was a significant inverse correlation between platelet count and PAIgG value of ITP patients. the PAIgG values of patients with aplastic anemia were within normal range.
No takes yet. Share an insight, caveat, or question.
Tsubakio et al. (2009) studied this question.