In 1978, Wagner described a technique using multiple Kirschner wires (K-wires) to stabilize an intertrochanteric osteotomy performed for the correction of coxa vara in small children. Multiple K-wires are used to create a custom high-angle blade plate for valgus osteotomy. The authors have evaluated a retrospective series of 17 Wagner intertrochanteric osteotomies that were performed in 10 children with coxa vara between the ages of 1 year and 8 years. The neck-shaft angle was corrected from 93.5 degrees to 129.5 degrees at long-term follow-up, and the Hilgenreiner epiphyseal angle was corrected from 71 degrees to 37.6 degrees at long-term follow-up. Revision surgery was performed on five hips with inadequate initial surgical correction. Complications included a single broken K-wire, a femur fracture after hardware removal, and one hip developed avascular necrosis postoperatively.
No takes yet. Share an insight, caveat, or question.
Widmann et al. (2001) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: