We design and demonstrate a resonant-type differential photodetector for a low-noise quantum homodyne measurement at 500 MHz optical sideband with 17 MHz of bandwidth. By using a microwave monolithic amplifier and a discrete voltage buffer circuit, a low-noise voltage amplifier is realized and applied to our detector. 12 dB of signal-to-noise ratio of the shot noise to the electric noise is obtained with 5 mW of a continuous-wave local oscillator. We analyze the frequency response and the noise characteristics of a resonant photodetector, and the theoretical model agrees with the shot noise measurement.