Key result
Internal jugular vein catheterization can cause Horner syndrome, most commonly manifesting as ptosis (22 of 22 patients) and miosis (21 of 22 patients).
Why the study?
The risk factors, clinical manifestations, and preventive measures of Horner syndrome caused by internal jugular vein catheterization needed to be explored.
Systematic Review (n=22)
Repeated puncture attempts and the use of anatomic landmark technique during internal jugular vein catheterization may increase the risk of Horner syndrome, which most commonly presents as ptosis and miosis.
Raises awareness of Horner syndrome after IJV catheterization; case reports leave optimal prevention strategies open.
THE RISK FACTORS, clinical manifestation, and preventive measures of Horner syndrome (HS) caused by internal jugular vein (IJV) catheterization were explored. Electronic databases were searched to identify all case reports of HS caused by IJV catheterization. Two authors independently extracted literature characteristics, IJV catheterization method, clinical manifestations, and prognosis data. Twenty case reports (22 patients in total) were included, 18 of which were written in English and the other 2 in Chinese. Patients were between 19 months to 65 years old, and clinical manifestations included ptosis (n = 22), miosis (n = 21), anhidrosis (n = 8), enophthalmos (n = 3), and hoarseness (n = 1). Onset of HS manifestation ranged from a few hours to 19 days after the procedure. Eight patients with ptosis, 6 patients with miosis, and 1 patient with hoarseness recovered during follow-up. Of the 22 patients, 8 underwent more than 1 attempt of IJV catheterization. Six patients experienced accidental carotid artery puncture or hematoma formation during or after IJV catheterization. Ultrasound guidance was applied in 4 patients and anatomic landmark technique was used in the other 18 patients. The left IJV was catheterized in 3 patients, and the right IJV was catheterized in 19 patients. Repeated attempts of puncture, anatomic landmark technique, accidental carotid artery puncture, or hematoma formation may increase the possibility of HS. Ptosis and miosis are the most common manifestations of HS caused by IJV catheterization.
No takes yet. Share an insight, caveat, or question.
Zou et al. (2019) conducted a systematic review in Horner syndrome caused by internal jugular vein catheterization (n=22). Internal jugular vein catheterization was evaluated on Clinical manifestations of Horner syndrome. Internal jugular vein catheterization can cause Horner syndrome, most commonly manifesting as ptosis (22 of 22 patients) and miosis (21 of 22 patients).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: