Answers are grounded in this paper and cite their sources.
Experimental study demonstrates accurate state-of-charge tracking in lithium cobalt oxide batteries under severe noise, indicating enhanced reliability for battery management systems.
Accurate state-of-charge estimation is essential for the safe and efficient operation of lithium-ion battery management systems. However, measurement outliers, time-varying noise statistics, model mismatch, and abrupt operating-condition changes can degrade the accuracy and stability of conventional Kalman-filter-based estimators. To address these problems, this study develops an adaptive generalized maximum correntropy strong-tracking cubature Kalman filter (AGMCC-STCKF) for a pouch-type lithium cobalt oxide battery. The principal methodological contribution is a residual-statistics-based adaptive kernel-width strategy. At each sampling instant, the kernel width is updated using a weighted combination of the standard deviation of a sliding innovation-residual window and the instantaneous innovation magnitude, followed by bounded projection to prevent kernel-width degeneration. The generalized maximum correntropy criterion is used to attenuate abnormal measurements, while the strong-tracking fading factor and Sage–Husa estimator improve responsiveness to model mismatch and time-varying noise statistics, respectively. A second-order RC equivalent-circuit model is established, and its parameters are identified using forgetting-factor recursive least squares. Experimental validation is conducted at 25 °C under UDDS and DST operating conditions. Across 30 paired Gaussian-noise realizations, the proposed method achieves mean MAE, RMSE, and MaxAE values of 0.4040%, 0.4571%, and 0.8653%, respectively, corresponding to reductions of 19.15%, 28.51%, and 72.50% relative to CKF. Under weak, medium, and strong non-Gaussian disturbances, the proposed method also achieves the lowest mean errors among the compared CKF-based estimators. External validation using the CALCE CS2_35 dataset yields an RMSE of 0.7183%. The mean single-step runtime is 0.871 ms, which is substantially lower than the 1 s sampling interval. These results demonstrate improved estimation accuracy and robustness within the investigated cell type, temperature, and operating conditions.
No takes yet. Share an insight, caveat, or question.
Cheng et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: