The crystallographic orientation of magnetite (Fe3O4) thin films was measured using electron backscatter diffraction (EBSD). Misorientation boundaries appear in maps of angular misorientation data. The distribution of misorientation angles changes after annealing the samples in air at 250degC. Most small-angle misorientations (<5deg) are removed after one minute of annealing, whereas larger misorientations (as high as 60deg) continue to persist
No takes yet. Share an insight, caveat, or question.
Koblischka‐Veneva et al. (2006) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context:
More from IEEE Transactions on Magnetics