Key result
Preimplantation right ventricular systolic pressure ≥75% was associated with a 3.36% worse right ventricular global longitudinal strain compared to the lowest RVSP group (p=0.014).
Why the study?
Mixed pulmonary regurgitation and stenosis in rTOF negatively impacts ventricular health, and whether predominant PS lowers RV GLS prior to and post-TPVR is unknown.
Does the severity of pulmonary stenosis impact right ventricular global longitudinal strain in repaired tetralogy of Fallot patients undergoing transcatheter pulmonary valve replacement?
Cohort (n=48)
Does the severity of pulmonary stenosis impact right ventricular global longitudinal strain in repaired tetralogy of Fallot patients undergoing transcatheter pulmonary valve replacement?
Answers are grounded in this paper and cite their sources.
In patients with repaired tetralogy of Fallot, significant pulmonary stenosis is associated with worse right ventricular global longitudinal strain, suggesting that earlier pulmonary valve replacement may be beneficial before relying solely on RV size and ejection fraction.
BACKGROUND: Mixed pulmonary disease with pulmonary regurgitation (PR) and stenosis (PS) in repaired tetralogy of Fallot (rTOF) can negatively impact ventricular health. Myocardial strain has been shown to be more sensitive at detecting occult ventricular dysfunction compared to right ventricular ejection fraction (RV EF). We hypothesize that rTOF patients with predominant PS will have lower RV global longitudinal strain (RV GLS) prior to and post-transcatheter pulmonary valve replacement (TPVR). METHODS: A retrospective cohort of rTOF patients who underwent cardiac magnetic resonance (CMR) and cardiac catheterization for right ventricular pressure (RVSP) measurement were analyzed at three time points: before valve implantation, at discharge and within 18 months post-TPVR. Patients were dichotomized into three groups based on RVSP: 0%-49%, 50%-74%, and >75%. RV GLS and left ventricular (LV) GLS by speckle tracking echocardiography (STE) were obtained from the apical 4-chamber using TomTec software (TOMTEC IS, Germany). RESULTS: Forty-eight patients were included. Every 14.3% increase in preimplantation RVSP above 28% was associated with an absolute magnitude 1% lower RV GLS (p = .001). Preimplantation RVSP when 75% or higher had 3.36% worse RV GLS than the lowest bin (p = .014). Overall, average RV strain magnitude was higher when preimplantation RVSP was less than 50% and had greater improvement over the three time points. Higher post implantation RVSP correlated with lower strain magnitude. CONCLUSION: Patients with significant PS (>50%) may benefit from earlier PVR and not depend solely on RV size and EF. Myocardial strain may be a more sensitive marker of function; however, larger, prospective studies are needed.
No takes yet. Share an insight, caveat, or question.
Williams et al. (2024) conducted a cohort in Repaired tetralogy of Fallot (rTOF) (n=48). Higher preimplantation right ventricular systolic pressure (RVSP) vs. Lower preimplantation RVSP was evaluated on Right ventricular global longitudinal strain (RV GLS) (3.36% worse RV GLS, p=0.014). Preimplantation right ventricular systolic pressure ≥75% was associated with a 3.36% worse right ventricular global longitudinal strain compared to the lowest RVSP group (p=0.014).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: