The influence of the driving frequency on the wall charge and voltage is experimentally investigated for the surface discharge of AC plasma display panels. A square pulse with a rising time of 150 ns and a duty ratio of 40% was used in the experiment. It is found that the capacitance C 0 of the surface discharge in a gas-filled region is almost constant and is 0.3 pF/cell, whereas the capacitance C g in the dielectric region is significantly decreased from 7.5 pF/cell to 0.8 pF/cell, as the driving frequency is increased from 10 kHz to 200 kHz. It is also found that both the wall charge and the wall voltage decrease from 34.5 pC/cell to 15.6 pC/cell and from 104.4 V to 76.5 V, respectively, as the driving frequency increases from 10 kHz to 200 kHz.