BACKGROUND: The effects of freezing-thawing cycles on intramedullary bone-implant interfaces have been studied in a rat model in mechanical pull-out tests. IMPLANTS: Twenty TiAl6V4 rods (Ø 0.8 mm, length 10 mm) implanted in rat tibiae METHODS: 10 rats underwent bilateral tibial implantation of titanium rods. At eight weeks, the animals were sacrificed and tibiae harvested for biomechanical testing. Eight tibiae were frozen and stored at -20°C for 14 days, the remaining eight were evaluated immediately post-harvest. Pull-out tests were used to determine maximum force and interfacial shear strength. RESULTS: There were no significant differences between fresh and those of the frozen-thawed group in maximum force or in interfacial shear strength. CONCLUSION: Frozen Storage of rat tibiae containing implants at -20° C has no effects on the biomechanical properties of Bone/ Implant interface.
No takes yet. Share an insight, caveat, or question.
Michael Diefenbeck (2011) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: