Answers are grounded in this paper and cite their sources.
Twenty-three adults with fractures of the odontoid process are reviewed. Te possible reasons for the high rate of non-union in reported series are considered: these include the type of fracture, its displacement, the presence of a gap at the fracture site, imperfect reduction and inadequate immobilisation. Type 2 fractures (at the base of the odontoid process) are the commonest and also the most liable to nonunion. In their treatment, reduction is important; as seen in the lateral radiograph at least two-thirds of the fracture surfaces should be in contact. Skull traction is not advised and halo-cast fixation is the treatment of choice; with this method 87.5 per cent of recent odontoid fractures united.
No takes yet. Share an insight, caveat, or question.
Ryan et al. (1982) studied this question.