Key result
ECG during induced atrial fibrillation identified multiple accessory pathways in 66% of patients, compared to 32% during sinus rhythm and 55% during rapid atrial pacing.
Why the study?
Does 12-lead ECG during induced atrial fibrillation improve the identification of multiple accessory pathways compared to sinus rhythm or rapid atrial pacing?
Observational (n=148)
Does 12-lead ECG during induced atrial fibrillation improve the identification of multiple accessory pathways compared to sinus rhythm or rapid atrial pacing?
Induced atrial fibrillation during 12-lead ECG recording is a highly effective method for diagnosing and localizing multiple accessory pathways, outperforming sinus rhythm and rapid atrial pacing.
Induced AF ECG may improve multiple accessory pathway detection; hypothesis-generating and should not yet change practice.
The present investigation evaluates the ability of several electrocardiographic (ECG) and electrophysiologic methods to identify multiple accessory pathways in 47 patients in whom the presence and sites of multiple accessory pathways were confirmed intraoperatively. To establish ECG features that suggested the presence of multiple accessory pathways in these patients, we initially studied the 12-lead ECG during maximal preexcitation in 101 patients with single accessory pathways. Distinctive 12-lead ECG patterns were noted for six defined anatomic areas around the right and left atrioventricular groove. Multiple preexcited QRS morphologies, each typical for a separate accessory pathway, and atypical preexcited QRS morphologies were recorded during atrial fibrillation in 31 of 47 (66%) patients with multiple accessory pathways. By comparison, the ECG during sinus rhythm and rapid atrial pacing identified 14 (32%) and 26 (55%) of the patients, respectively. In 12 (26%) patients in whom evidence for multiple accessory pathways was absent from endocardial mapping data, atrial fibrillation provided the diagnosis. In five (11%) patients, atrial fibrillation was the only method that demonstrated the presence of multiple accessory pathways. A combination of ECG findings during atrial fibrillation and rapid atrial pacing plus endocardial mapping data identified 43 (91%) of the patients with multiple accessory pathways. There were two unique fusion patterns on the 12-lead ECG that were characteristic of specific multiple accessory pathway combinations.(ABSTRACT TRUNCATED AT 250 WORDS)
No takes yet. Share an insight, caveat, or question.
Fananapazir et al. (1990) conducted an observational in Multiple accessory pathways (n=148). ECG during induced atrial fibrillation vs. ECG during sinus rhythm and rapid atrial pacing was evaluated on Identification of multiple accessory pathways. ECG during induced atrial fibrillation identified multiple accessory pathways in 66% of patients, compared to 32% during sinus rhythm and 55% during rapid atrial pacing.