Single-Switch inverters such as the conventional Class-E inverter are often highly load sensitive, and maintain zero-voltage switching over only a narrow range of load resistances. This paper introduces a design methodology that enables rapid synthesis of Class E and related single-switch inverters that maintain ZVS operation over a wide range of resistive loads. We treat the design of Class-E inverters for variable resistance operation and show how the proposed methodology relates to circuit transformations on traditional Class-E designs. We also illustrate the use of this transformation approach to realize Φ2inverters for variable-resistance operation. The proposed methodology is demonstrated and experimentally validated at 27.12 MHz in a Class E and Φ2inverter designs that operate efficiently over 12:1 load resistance range for an 8:1 and 10:1 variation in output power, respectively, and a 25-W peak output power.
No takes yet. Share an insight, caveat, or question.
Rosłaniec et al. (2014) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: