Quartz crystal impedance around the resonant frequency at 10 MHz of a composite quartz crystal resonator has been studied simultaneously with cyclic voltammetry. A modified quartz crystal with a redox hydrogel (poly(allylamine)-ferrocene cross-linked with glucose oxidase) and immersed in liquid electrolyte was used. Impedance parameters (R(f) and X(L)((f))) of the surface redox gel film were obtained by fitting the resonator transfer function |V(o)/V(i)| vs ω to a BVD equivalent circuit and analyzed with the multiple nonpiezoelectric layer model of Martin. Two limiting hydrogel layers of the same composition were studied while oxidizing and reducing the ferrocene/ferricenium moieties attached to the swollen polymer backbone: thin and thick redox hydrogel films. For the thin films, the Sauerbrey approximation was valid. The mass/thickness and film viscosity changes that resulted from the anion and water exchange were evaluated while redox switching the polymer on the assumption of negligible storage modulus G' and a density of 1. For thick gel layers, on the other hand, the penetration depth of the acoustic wave was far less than the film thickness, and a liquid-like behavior was apparent. Film storage modulus and film loss modulus were simultaneously evaluated with the cyclic voltammetry.
No takes yet. Share an insight, caveat, or question.
Etchenique et al. (1997) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: