Pitch, timbre, and/or timing cues may be used to stream and segregate competing musical melodies and instruments. In this study, melodic contour identification was measured in cochlear implant (CI) and normal-hearing (NH) listeners, with and without a competing masker; timing, pitch, and timbre cues were varied between the masker and target contour. NH performance was near-perfect across different conditions. CI performance was significantly poorer than that of NH listeners. While some CI subjects were able to use or combine timing, pitch and/or timbre cues, most were not, reflecting poor segregation due to poor spectral resolution.
No takes yet. Share an insight, caveat, or question.
Zhu et al. (2011) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: