Key result
Cryothermal ablation and radiofrequency ablation for atrioventricular nodal reentrant tachycardia were equally effective, with an overall acute procedural success rate of 96% and no significant difference in long-term redo procedures.
Why the study?
Does cryoablation compared to radiofrequency ablation improve safety and maintain efficacy in patients with atrioventricular nodal reentrant tachycardia?
Observational (n=274)
No
Does cryoablation compared to radiofrequency ablation improve safety and maintain efficacy in patients with atrioventricular nodal reentrant tachycardia?
Answers are grounded in this paper and cite their sources.
Cryoablation and radiofrequency ablation for AVNRT are equally effective long-term, but cryoablation has a better safety profile regarding inadvertent atrioventricular block.
BACKGROUND: Radiofrequency (RF) catheter ablation for atrioventricular nodal reentrant tachycardia (AVNRT) is highly successful but carries a risk for inadvertent atrioventricular block. Cryoablation (cryo) has the potential to assess the safety of a site before the energy is applied. PURPOSE: The aim of this study was to evaluate the long-term efficacy and safety of cryothermal ablation in a large series of patients and compare it to RF. METHODS: All consecutive routinely performed AVNRT ablations from our centre between 1999 and 2007 were retrospectively analysed. RESULTS: In total, 274 patients were elegible: 150 cryoablations and 124 RF. Overall procedural success was 96% (262/274), and equal in both groups, but nine patients were crossed to another arm. Mean fluoroscopy time was longer in the group treated with RF (27 ± 22 min vs. cryo 19 ± 15 min; p = 0.002). Mean procedure time was not different (RF 138 ± 71 min vs. cryo 146 ± 60 min). A permanent pacemaker was necessary in two RF patients. The questionnaire revealed a high incidence of late arrhythmia related symptoms (48%), similar in both groups, with improved perceived quality of life. The number of redo procedures for AVNRT over 4.3 ± 2.5-years follow-up was not statistically different (11% after cryo and 5% after RF). CONCLUSIONS: Our data confirm that cryo and RF ablation with 4-mm tip catheters for AVNRT are equally effective, even after long-term follow-up.
No takes yet. Share an insight, caveat, or question.
Schwagten et al. (2010) conducted an observational in Atrioventricular nodal reentrant tachycardia (AVNRT) (n=274). Cryothermal ablation vs. Radiofrequency ablation was evaluated on Acute procedural success (p=NS). Cryothermal ablation and radiofrequency ablation for atrioventricular nodal reentrant tachycardia were equally effective, with an overall acute procedural success rate of 96% and no significant difference in long-term redo procedures.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: