Key result
Instantaneous venous saturation estimated from PPG waveforms was significantly lower (median 79.3%) than time-domain arterial saturation (median 101.2%) in patients undergoing cardiothoracic surgery.
Why the study?
Does time-frequency analysis of oesophageal PPG signals allow for the estimation of instantaneous venous blood saturation in patients undergoing cardiothoracic surgery?
Observational (n=12)
Does time-frequency analysis of oesophageal PPG signals allow for the estimation of instantaneous venous blood saturation in patients undergoing cardiothoracic surgery?
Time-frequency analysis of oesophageal PPG signals can isolate ventilator modulations to estimate instantaneous venous blood saturation, which is significantly lower than arterial saturation as expected.
Answers are grounded in this paper and cite their sources.
Venous saturation estimation via oesophageal PPG time-frequency analysis is feasible; hypothesis-generating and should not yet change practice.
Non-invasive estimation of regional venous saturation (SxvO2) using a conventional pulse oximeter could provide a means of obtaining clinically relevant information. This study was carried out in order to investigate the hypothesis that SxvO2 could be estimated by utilising the modulations created by positive pressure ventilation in the photoplethysmograph (PPG) signals. The modulations caused by the mechanical ventilator were extracted from oesophageal PPG signals obtained from 12 patients undergoing cardiothoracic surgery. The signals analysed in this work were acquired in a previous study. For the purpose of this analysis the raw PPG signal was considered to have three major components, ac PPG signal (cardiac related component), a static component or dc PPG signal (created mostly by the absorption of light by surrounding tissue) and the ventilator modulation component. These components were then used to estimate instantaneous arterial blood oxygen saturation (SpO2) and SxvO2 by utilising time-frequency analysis technique of smoothed-pseudo Wigner-Ville distribution (SPWVD). The results showed that there was no significant difference in the traditionally-derived (time-domain) arterial saturation and the instantaneous arterial saturation. However, the instantaneous venous saturation was found to be significantly lower than the estimated time-domain and instantaneous arterial saturation (P = < 0.001, n = 12).
No takes yet. Share an insight, caveat, or question.
Shafqat et al. (2015) conducted an observational in Cardiothoracic surgery (n=12). Photoplethysmograph (PPG) waveform analysis using SPWVD vs. Time-domain and instantaneous arterial saturation was evaluated on Instantaneous venous saturation compared to arterial saturation (p=<0.001). Instantaneous venous saturation estimated from PPG waveforms was significantly lower (median 79.3%) than time-domain arterial saturation (median 101.2%) in patients undergoing cardiothoracic surgery.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: