In this work, we present a new graphene-based sensor designed to monitor a set of photovoltaic panels on a sound-absorbing screen in terms of their potential mechanical damage. The innovative design of the photovoltaic module and consequently its sound-reflecting and sound-absorbing parameters play a vital role. The light transmittance of the sensor layer composed of graphene flakes in a cellulose matrix, confirmed by optical studies, allows its use directly over the photovoltaic cells. All the sensors are interconnected with metallic connections to reduce their internal resistance on larger surfaces. The sensor state is monitored through the resistance value as a zero-one operation/damaged response. Two sensor damage, scenarios, repetitive scratching, and cutting-out were described. The sensor measurements were performed in the potential ranging from 2.1 to 51.1 V, and the current response allowed to calculate the total resistance. The change in sensor resistance ranged between 9.3 and 24.1%, depending on the damaged area. The resistance for the scratched surface oscillated between 25 and 26 Ω, whereas the cut-out surface showed values more than 1.5 times higher. The proposed sensor based on graphene, cellulose, and ethylene–vinyl acetate allows the registration of immediate information about the destruction or theft of a power node.
No takes yet. Share an insight, caveat, or question.
Januszko et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: