Key result
Orthostatic decreases in cardiac chaos during the head-up tilt test specifically identified patients with vasovagal syncope, yielding an area under the curve of 0.93 (p<0.001) with 85.7% sensitivity and 96.2% specificity.
Why the study?
Does nonlinear analysis of heart rate variability (cardiac chaos) during head-up tilt testing identify orthostatic intolerance in patients with vasovagal syncope?
Case-Control (n=40)
No
Does nonlinear analysis of heart rate variability (cardiac chaos) during head-up tilt testing identify orthostatic intolerance in patients with vasovagal syncope?
Nonlinear analysis of heart rate variability to detect a decrease in cardiac chaos during head-up tilt testing can accurately identify patients with vasovagal syncope, even when conventional tilt test results are negative.
Answers are grounded in this paper and cite their sources.
May aid vasovagal syncope diagnosis on tilt testing; hypothesis-generating and requires prospective validation before clinical adoption.
BACKGROUND: Autonomic dysfunction contributes to orthostatic intolerance in vasovagal syncope (VVS), but as it has not been identified by spectral analysis of heart rate variability (HRV) in previous studies, the present hypothesis was that nonlinear analysis of HRV would identify the orthostatic intolerance in VVS. METHODS AND RESULTS: Twenty-six patients with VVS and 14 matched controls were subjected to 80-degree head-up tilt test (positive: 13 patients; negative: 13 patients and 14 controls). There were no differences in the orthostatic changes in the indices of spectral analyses of HRV among the 3 groups. The Lyapunov exponent (LE) was calculated from 200 consecutive RR-intervals to investigate chaotic behavior, and cardiac chaos was defined as the incidence of the presence of a positive finite LE. Orthostatic decreases in cardiac chaos were observed in the VVS patients (both the positive and negative groups), although there was no orthostatic decrease in the control group (ANOVA: p = 0.008). The receiver-operator characteristic curve indicated that cardiac chaos during the tilt identified VVS regardless of the results of the tilt (p < 0.001, sensitivity: 85.7%, specificity: 96.2%). CONCLUSIONS: The decrease in cardiac chaos during the tilt test was specific to patients with VVS, even if their response to the test was negative.
No takes yet. Share an insight, caveat, or question.
Suzuki et al. (2006) conducted a case-control in Vasovagal syncope (n=40). Head-up tilt test (HUT) vs. Healthy controls was evaluated on Orthostatic decrease in cardiac chaos (presence of positive finite Lyapunov exponent) during head-up tilt test (AUC 0.93, p=<0.001). Orthostatic decreases in cardiac chaos during the head-up tilt test specifically identified patients with vasovagal syncope, yielding an area under the curve of 0.93 (p<0.001) with 85.7% sensitivity and 96.2% specificity.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: