Adsorbed sulfur is a poison to the Pt catalysts used in proton exchange membrane fuel cells, but it can be removed by potential cycling. This process is studied for S x -poisoned nanoscale Pt− and Pt 3 Co− on Vulcan carbon (Pt/VC and Pt 3 Co/VC) in perchloric acid electrolyte using the Δμ adsorbate isolation technique for in situ X-ray absorption spectroscopy. The Δμ technique is modified to better distinguish the Δμ signatures for H, O, and S x on Pt. The resulting Δμ analysis suggests that SO 2 on nanoscale Pt is oxidized to bisulfate or sulfate species in two regions, near 1.05 V on the cluster edges of the Pt nanoparticle, and at higher potentials from the Pt(111) faces where oxygen is less strongly bound. The bisulfate or sulfate species desorb from the Pt surface at high potentials due to O(OH) adsorption/replacement and at low potentials due to loss of the Coulomb attraction between the bisulfate anion and the Pt. A similar oxidation process occurs for S x -poisoned Pt 3 Co/VC, but at lower potentials because a ligand effect coming from Co shifts the oxidization potential of adsorbed SO 2 to lower potentials while pushing OH adsorption to higher potentials. The spectroscopic results give insights into cyclic voltammetry data and are consistent with electrochemical cycling procedures for removing the sulfur.
No takes yet. Share an insight, caveat, or question.
Ramaker et al. (2010) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: