The design and operation of a novel type of magnetostatic wave transducer is described. The transducer is formed from an interdigital arrangement of narrow, open circuited microstrip fingers, each half an electromagnetic wavelength long. Experimental results in the frequency range 9–9.4 GHz are presented for 2, 4 and 10 finger transducers which are in good agreement with the sin(Nx/2)/sin(x/2) response predicted by simple theory.