A solid‐state proton conductor (antimonic acid) sensor capable of detecting dilute hydrogen in air at room temperature has been developed. The sensor element has a four‐probe type structure with two inner Ag probes and two outer Pt electrodes. With the outer electrodes short‐circuited, the potential difference between the two inner probes was used as a signal output. It was found that the output was not only proportional to hydrogen concentration (up to 1.3%) in air, but also independent of relative humidity (7–90%). The 90% response time was as short as 20s to 0.2% at 25°C. The signal output had a small positive temperature coefficient ( ca. 2 mV/°C) in the range from 10° to 35°C. The sensor was fairly stable during the test period of about one month. A hydrogen sensing mechanism was proposed and discussed with supporting evidence about electric potential profiles inside the proton conductor.
No takes yet. Share an insight, caveat, or question.
Miura et al. (1989) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: