Answers are grounded in this paper and cite their sources.
An electrolytic tilt sensor has been designed and fabricated using micro electro mechanical systems (MEMS) technique. The anisotropic KOH etching is used to form a deep Si cavity where conductive electrolyte solution is filled in. Au/NiCr electrodes are simultaneously deposited and patterned using e-beam evaporator with an aligned shadow mask, which is fabricated by through-wafer via etching on a 400-µm-thick Si wafer. A composite electrolyte of 4.8 µL in the volume is filled in the anisotropically-etched cavity that has a volume of 7.3 µL. The electrolyte solution is comprised of variable amount of KCl and a mixture of deionized (DI) water, ethanol and methanol (50, 25, and 25 vol %, respectively). When the electrolyte is injected into the cavity, a cover glass is bonded to seal the electrolyte solution. The fabricated electrolytic tilt sensor is excited by an alternating current to prevent electrolysis in the electrolyte-filled cavity and measured by Wheatstone bridge setup that reads the variation of resistance with respect to an incoming inclination. The measured output characteristic of the MEMS-based electrolytic tilt sensor is as good as that of a conventional electrolytic tilt sensor. Moreover, MEMS-based sensor prevails in its small size, low cost and possible mass production.
No takes yet. Share an insight, caveat, or question.
Kang et al. (2006) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: