Answers are grounded in this paper and cite their sources.
The highly sensitive CO2detective instrument is intensively studied recently for the atmosphere protection. Fiber-optic interferometer is widely used as a gas sensor because its interference wavelength can be influenced by the environmental refractive index. In this work, by adopting the nanoparticles self-assembly technology, a spherical optical device with a primary pore width of 8.13 nm and a specific surface area as large as 74.58 m2/g is fabricated. For gas detection, the larger the specific surface area of the device, the more gas molecules being adsorbed, resulting in a higher sensitivity. A Fabry-Perot fiber-optic interferometer is designed by mounting the self-assembled device on a fiber end face. In the experiment, it shows a fast response time of 21 s, a high wavelength sensitivity of 200 pm/%, and a wide detection range from 350 ppm to 36% for CO2gas. It also performs a high selectivity, good repeatability, and immunity to the gas flow rate. Such a Fabry-Perot interferometer, as a standard lab-on-fiber device, will have a significant application potential for trace CO2monitoring in the field of carbon capture, utilization, and storage (CCUS).
No takes yet. Share an insight, caveat, or question.
Yue et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: