We demonstrated a delay-line interferometer (DLI)-based, optical-signal-to-noise ratio (OSNR) monitoring scheme of 100 Gbit/s polarization multiplexed quadrature-phase-shift-keying (PM-QPSK) four-channel WDM at 50-GHz International Telecommunication Union (ITU) grid with <0.5 dB error for signals with up to 26 dB of actual OSNR. We also demonstrated data format transparency and baud rate tunability of the OSNR monitor by measuring the OSNR for a 200 Gbit/s PM-16-QAM (25-Gbaud) signal and a 200 Gbit/s PM-QPSK (50-Gbaud) signal. We also explored and studied different monitor parameters, including the shape of the filter spectrum, the bandwidth of the filter, DLI delay, and DLI phase-detuning to determine the design guidelines for a desired level of accuracy for the OSNR monitor in an optical network.
No takes yet. Share an insight, caveat, or question.
Chitgarha et al. (2014) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: