Key result
An automated Padua Prediction Score algorithm using EHR data had a sensitivity of 46% and specificity of 94% for detecting patients at high risk for VTE compared to manual extraction.
Why the study?
Does an automated Padua Prediction Score (APPS) using EHR data accurately classify VTE risk compared to manual data extraction in hospitalized older adults?
Cohort (n=311)
Does an automated Padua Prediction Score (APPS) using EHR data accurately classify VTE risk compared to manual data extraction in hospitalized older adults?
An automated Padua Prediction Score using EHR data had high specificity but poor sensitivity for identifying high VTE risk in hospitalized older adults, making it suboptimal as a stand-alone tool.
Answers are grounded in this paper and cite their sources.
Poor sensitivity limits automated VTE screening utility; leaves open refinement and prospective validation of EHR algorithms.
OBJECTIVE: Venous thromboembolism (VTE) prophylaxis is an important consideration for hospitalized older adults, and the Padua Prediction Score (PPS) is a risk prediction tool used to prioritize patient selection. We developed an automated PPS (APPS) algorithm using electronic health record (EHR) data. This study examines the accuracy of APPS and its individual components versus manual data extraction. METHODS: This is a retrospective cohort study of hospitalized general internal medicine patients, aged 70 and over. Fourteen clinical variables were collected to determine their PPS; APPS used EHR data exports from health system databases, and a trained abstractor performed manual chart abstractions. We calculated sensitivity and specificity of the APPS, using manual PPS as the gold standard for classifying risk category (low vs. high). We also examined performance characteristics of the APPS for individual variables. RESULTS: PPS was calculated by both methods on 311 individuals. The mean PPS was 3.6 (standard deviation, 1.8) for manual abstraction and 2.8 (1.4) for APPS. In detecting patients at high risk for VTE, the sensitivity and specificity of the APPS algorithm were 46 and 94%, respectively. The sensitivity for APPS was poor (range: 6-34%) for detecting acute conditions (i.e., acute myocardial infarction), moderate (range: 52-74%) for chronic conditions (i.e., heart failure), and excellent (range: 94-98%) for conditions of obesity and restricted mobility. Specificity of the automated extraction method for each PPS variable was > 87%. CONCLUSION: APPS as a stand-alone tool was suboptimal for classifying risk of VTE occurrence. The APPS accurately identified high risk patients (true positives), but lower scores were considered indeterminate.
No takes yet. Share an insight, caveat, or question.
Pavon et al. (2018) conducted a cohort in Venous thromboembolism risk (n=311). Automated Padua Prediction Score (APPS) algorithm vs. Manual data extraction was evaluated on Detecting patients at high risk for VTE. An automated Padua Prediction Score algorithm using EHR data had a sensitivity of 46% and specificity of 94% for detecting patients at high risk for VTE compared to manual extraction.
Synapse has enriched 10 related papers. Consider them for comparative context: