PURPOSE: To evaluate the effects and safety of laser in situ keratomileusis (LASIK) and diode thermal keratoplasty (DTK) for correction of moderate to high hyperopia (+5.00 to +10.00 D). METHODS: This prospective study included 30 eyes of 15 patients who had LASIK-DTK bioptics. The median age of the patients was 50.5 years. LASIK was performed using a Nidek EC-5000 excimer laser system and DTK by a Prolaser DTK laser, 2 months after LASIK. Follow-up ranged from 9 to 12 months (mean, 10.5 mo). RESULTS: The mean preoperative spherical equivalent refraction was +8.25 +/- 0.25 D and mean postoperative was +1.00 +/- 0.50 D. The preoperative best spectacle-corrected visual acuity (BSCVA) was < or = 20/40 in 10 eyes and > or = 20/25 in 20 eyes. Postoperatively, BSCVA was < or = 20/40 in 8 eyes and > or = 20/25 in 22 eyes. No significant intra- or postoperative complications occurred. CONCLUSION: LASIK-DTK bioptics for correction of moderate to high hyperopia (+5.00 to +10.00 D) was safe and effective. In this method, two different ablative and non-ablative laser systems were used to compensate for regression, which is the most important concern in the correction of hyperopia.
No takes yet. Share an insight, caveat, or question.
Rad et al. (2002) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: