Key result
The Wisconsin Miniature Swine brachial plexus has significantly fewer myelinated axons in median (p=0.0049), ulnar (p=0.0002), and musculocutaneous nerves (p=0.0454) compared to humans.
Why the study?
Rodent models of brachial plexus injury poorly mimic human injury due to size discrepancies, prompting evaluation of Wisconsin Miniature Swine as a suitable model.
The Wisconsin Miniature Swine brachial plexus is similar in size and origin to humans, making it a suitable model to study brachial plexus injury.
Swine brachial plexus models may underestimate human axon counts; leaves open suitability for injury research despite anatomic similarities.
Brachial plexus injury (BPI) occurs when the brachial plexus is compressed, stretched, or avulsed. Although rodents are commonly used to study BPI, these models poorly mimic human BPI due to the discrepancy in size. The objective of this study was to compare the brachial plexus between human and Wisconsin Miniature Swine TM (WMS TM ), which are approximately the weight of an average human (68–91 kg), to determine if swine would be a suitable model for studying BPI mechanisms and treatments. To analyze the gross anatomy, WMS brachial plexuses were dissected both anteriorly and posteriorly. For histological analysis, sections from various nerves of human and WMS brachial plexuses were fixed in 2.5% glutaraldehyde, and postfixed with 2% osmium tetroxide. Subsequently paraffin sections were counter‐stained with Masson's Trichrome. Gross anatomy revealed that the separation into three trunks and three cords is significantly less developed in the swine than in human. In swine, it takes the form of upper, middle, and lower systems with ventral and dorsal components. Histological evaluation of selected nerves revealed differences in nerve trunk diameters and the number of myelinated axons in the two species. The WMS had significantly fewer myelinated axons than humans in median ( p = 0.0049), ulnar ( p = 0.0002), and musculocutaneous nerves ( p = 0.0454). The higher number of myelinated axons in these nerves for humans is expected because there is a high demand of fine motor and sensory functions in the human hand. Due to the stronger shoulder girdle muscles in WMS, the WMS suprascapular and axillary nerves were larger than in human. Overall, the WMS brachial plexus is similar in size and origin to human making them a very good model to study BPI. Future studies analyzing the effects of BPI in WMS should be conducted.
No takes yet. Share an insight, caveat, or question.
Hanna et al. (2021) studied Brachial plexus injury. Wisconsin Miniature Swine (WMS) brachial plexus vs. Human brachial plexus was evaluated on Number of myelinated axons and gross anatomy. The Wisconsin Miniature Swine brachial plexus has significantly fewer myelinated axons in median (p=0.0049), ulnar (p=0.0002), and musculocutaneous nerves (p=0.0454) compared to humans.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: