Key result
D-dimer testing maintained high sensitivity and negative predictive value for ruling out VTE across all age categories, despite an age-dependent decrease in specificity.
Why the study?
Does D-dimer measurement reliably rule out VTE in low- and intermediate-risk patients across different age categories?
Observational (n=1,004)
Does D-dimer measurement reliably rule out VTE in low- and intermediate-risk patients across different age categories?
D-dimer testing maintains high sensitivity and negative predictive value for ruling out VTE across all age groups, despite decreased specificity in older patients.
Answers are grounded in this paper and cite their sources.
Supports D-dimer for VTE rule-out across ages; leaves open whether age-adjusted thresholds improve specificity in prospective validation.
Background. Strategies combining pretest clinical assessment and D-dimers measurement efficiently and safely rule out venous thromboembolism events (VTE) in low- and intermediate-risk patients. Objectives. As process of ageing is associated with altered concentrations of coagulation markers including an increase in D-dimers levels, we investigated whether D-dimers could reliably rule out VTE across age categories. Method. We prospectively assessed the test performance in 1,004 patients visiting the emergency department during the 6-month period with low or intermediate risk of VTE who also received additional diagnostic procedures. Results. 67 patients had VTE with D-dimers levels above the threshold, and 3 patients displayed D-dimers levels below the threshold. We observed that specificity of D-dimers test decreased in an age-dependent manner. However, sensitivity and negative predictive value remained at very high level in each age category including older patients. Conclusion. We conclude that, even though D-dimers level could provide numerous false positive results in elderly patients, its high sensitivity could reliably help physicians to exclude the diagnosis of VTE in every low- and intermediate-risk patient.
No takes yet. Share an insight, caveat, or question.
Sahakian et al. (2010) conducted an observational in Venous thromboembolism (VTE) (n=1,004). D-dimers measurement was evaluated on Accuracy of D-dimers to rule out VTE. D-dimer testing maintained high sensitivity and negative predictive value for ruling out VTE across all age categories, despite an age-dependent decrease in specificity.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: