Key result
A new scintigraphic method for evaluating local blood volume reductions in extremities demonstrated a significant correlation with the plethysmographic method (r = 0.42, p = 0.018).
Why the study?
Does a scintigraphic method using 99mTc-radiolabelled erythrocytes accurately evaluate reductions in local blood volumes in human extremities compared to plethysmography?
Does a scintigraphic method using 99mTc-radiolabelled erythrocytes accurately evaluate reductions in local blood volumes in human extremities compared to plethysmography?
Effect estimate: r = 0.42
p-value: p=0.018
A novel scintigraphic method using 99mTc-radiolabelled erythrocytes is precise and correlates with plethysmography for evaluating local blood volume reductions in human extremities.
May support scintigraphic blood volume assessment; leaves open clinical adoption pending larger validation studies.
We introduce a new method for evaluating reductions in local blood volumes in extremities, based on the combined use of autologue injection of 99mTc-radiolabelled erythrocytes and clamping of the limb blood flow by the use of a tourniquet. Twenty-two healthy male volunteers participated in the experiment. Evaluation of one versus two scintigraphic projections, trials for assessment of the reproducibility, a comparison of the scintigraphic method with a water-plethysmographic method and registration of the fractional reduction in blood volume caused by exsanguination as a result of simple elevation were carried out. No significant differences between results obtained by the use of one or two scintigraphic projections were found. The between-subject coefficient of variation was 14% in the lower limb experiment and 11% in the upper limb experiment. The within-subject coefficient of variation was 6% in the lower limb experiment and 6% in the upper limb experiment. We found a significant relation (r = 0.42, p = 0.018) between the results obtained by the scintigraphic method and the plethysmographic method. In fractions, a mean reduction in blood volume of 0.49+0.14 (2 SD) was found after 1 min of elevation of the lower limb and a mean reduction of 0.45+/-0.10 (2 SD) after half a minute of elevation of the upper limb. We conclude that the method is precise and can be used in investigating physiologic and pathophysiologic mechanisms in relation to blood volumes of limbs not subject to research previously.
No takes yet. Share an insight, caveat, or question.
Lars Blønd (2000) studied Healthy (n=22). Scintigraphic method vs. Water-plethysmographic method was evaluated on Correlation between scintigraphic and plethysmographic methods (r = 0.42, p=0.018). A new scintigraphic method for evaluating local blood volume reductions in extremities demonstrated a significant correlation with the plethysmographic method (r = 0.42, p = 0.018).