Key result
Combining two helical geometries of differing radii (R = 0.2 D and R = 0.5 D) produced a 70% increase in mixing compared with standard single helical designs.
Why the study?
Helical cardiovascular prostheses induce swirling flow and mixing to reduce thrombosis and hyperplasia, but whether combining differing helical radii enhances mixing effectiveness remained unknown.
Does combining differing small amplitude helical geometries improve mixing efficiency in cardiovascular prostheses compared to standard single helical designs?
Does combining differing small amplitude helical geometries improve mixing efficiency in cardiovascular prostheses compared to standard single helical designs?
Answers are grounded in this paper and cite their sources.
Combining differing small amplitude helical geometries in cardiovascular prostheses can significantly increase flow mixing, which may help reduce thrombosis and neo-intimal hyperplasia.
Helical geometries have been used in recent years to form cardiovascular prostheses such as stents and shunts. The helical geometry has been found to induce swirling flow, promoting in-plane mixing. This is hypothesised to reduce the formation of thrombosis and neo-intimal hyperplasia, in turn improving device patency and reducing re-implantation rates. In this paper we investigate whether joining together two helical geometries, of differing helical radii, in a repeating sequence, can produce significant gains in mixing effectiveness, by embodying a ‘streamline crossing’ flow environment. Since the computational cost of calculating particle trajectories over extended domains is high, in this work we devised a procedure for efficiently exploring the large parameter space of possible geometry combinations. Velocity fields for the single geometries were first obtained using the spectral/hp element method. These were then discontinuously concatenated, in series, for the particle tracking based mixing analysis of the combined geometry. Full computations of the most promising combined geometries were then performed. Mixing efficiency was evaluated quantitatively using Poincaré sections, particle residence time data, and information entropy. Excellent agreement was found between the idealised (concatenated flow field) and the full simulations of mixing performance, revealing that a strict discontinuity between velocity fields is not required for mixing enhancement, via streamline crossing, to occur. Optimal mixing was found to occur for the combination R = 0.2 D and R = 0.5 D , producing a 70 % increase in mixing, compared with standard single helical designs. The findings of this work point to the benefits of swirl disruption and suggest concatenation as an efficient means to determine optimal configurations of repeating geometries for future designs of vascular prostheses.
No takes yet. Share an insight, caveat, or question.
Cookson et al. (2019) studied Cardiovascular prostheses. Combining two helical geometries of differing helical radii (R = 0.2 D and R = 0.5 D) vs. Standard single helical designs was evaluated on Mixing efficiency (70% increase). Combining two helical geometries of differing radii (R = 0.2 D and R = 0.5 D) produced a 70% increase in mixing compared with standard single helical designs.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: