In this paper, the cross-coupling phenomenon in the wound-rotor synchronous starter/generator system is studied. Due to the armature reaction, the excitation field is dragged away from the d-axis by the armature magnetic field and the cross-coupling inductance Ldqexists. What is more, the cross-coupling phenomenon also occurs in the excitation field, it means not only the mutual inductance Mdfbetween the d-axis and excitation field exists, but also mutual inductance Mqfbetween the q-axis and excitation field exists. If this Mqfcomponent is ignored, this will result in a torque calculated error, especially facing an intense armature reaction, the error can be more than 20%. The mathematical expressions of cross-coupling inductance Ldq, Mqfare derived. Based on these expressions, a more accurate torque equation is proposed. The validity of the proposed analysis is proved by showing the agreement with experimental results and maximum torque per ampere (MTPA) loci.
No takes yet. Share an insight, caveat, or question.
Pang et al. (2018) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: