Key result
Point of care ultrasound using right ventricle outflow tract velocity time integral morphology successfully guided real-time monitoring of pulmonary vasodilator therapy in 1 asymptomatic patient.
Why the study?
Diagnosis of pulmonary hypertension and interstitial lung disease in systemic sclerosis is usually late, and point of care ultrasound may shorten diagnostic times and guide therapy.
Does POCUS using RVOT VTI morphology help guide pulmonary vasodilatory therapy in patients with systemic sclerosis associated pulmonary hypertension?
Case Report (n=1)
Does POCUS using RVOT VTI morphology help guide pulmonary vasodilatory therapy in patients with systemic sclerosis associated pulmonary hypertension?
Answers are grounded in this paper and cite their sources.
POCUS using RVOT VTI morphology is a valuable bedside tool for early diagnosis and therapy monitoring in systemic sclerosis-associated pulmonary hypertension.
Systemic sclerosis (SSc) is a chronic, autoimmune disease involving small vessels characterized by skin and internal organs fibrosis. Interstitial lung disease (ILD) is one of the main findings, along with pulmonary hypertension, as a marker of morbidity and mortality. Diagnosis is usually late, and therefore treatment is established in the advanced stages of the disease. Point of care ultrasound (POCUS) emerges as a tool at the bedside for shortening diagnostic times and guiding therapy. Here, we performed a multi‐organ POCUS, evidencing the presence of ILD and pulmonary hypertension in a patient with no cardiovascular symptoms suggestive of advanced disease. We did real‐time monitoring of pulmonary vasodilator therapy at the patient's bedside using right ventricle outflow tract velocity time integral morphology (RVOT VTI). Midsystolic notching of RVOT VTI is highly specific for pulmonary hypertension. POCUS is a valuable tool that could improve diagnostic times and optimize therapy monitoring in asymptomatic patients with early manifestations of organic involvement in patients with SSc. This case demonstrates the value of POCUS as a follow‐up tool in treating patients with SSc.
No takes yet. Share an insight, caveat, or question.
Velasco‐Malagón et al. (2024) conducted a case report in Systemic sclerosis associated pulmonary hypertension (n=1). Point of care ultrasound (POCUS) with RVOT VTI morphology was evaluated. Point of care ultrasound using right ventricle outflow tract velocity time integral morphology successfully guided real-time monitoring of pulmonary vasodilator therapy in 1 asymptomatic patient.
Synapse has enriched 10 related papers. Consider them for comparative context: