This is the authors' abstract. We don't add key points for this paper.
This study investigates the influence of reflux-hole height on self-priming performance in a vortex self-priming pump. Three-dimensional transient simulations were performed using an Eulerian volume-of-fluid model, and Liutex-based vortex identification and local entropy production analysis were employed to reveal the coupling between vortex structures and irreversible energy loss. The baseline pump without a reflux hole serves as the reference case. Results show a distinctly non-monotonic effect of reflux-hole height: a low-position hole (58 mm) increases the inlet gas mass flow rate by 41% relative to baseline and reduces the self-priming time from 2.35 to 1.65 min, whereas intermediate heights (88–99 mm) degrade performance due to back-pressure accumulation, liquid-ring discontinuity, and blockage vortices. The optimal high-position hole (114 mm) achieves a 62% increase in gas mass flow and shortens self-priming time to 1.45 min. Entropy production analysis indicates that turbulent dissipation dominates energy loss, with severe irreversible loss arising mainly from shear-dominated deformation around vortex boundaries rather than rigid-body rotation. Within the tested pump geometry and operating conditions, intermediate reflux-hole heights should be avoided, while a high-position reflux hole near the gas-discharge side maximizes gas evacuation and minimizes nonproductive energy dissipation.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Cui et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: