The effect of a quaternary nitrogen compound, Emepronium bromide (Cetiprin), on micturition parameters was investigated. In seven healthy subjects, a pronounced effect on the intravesical pressure and on the urinary flow was found with a decrease of 32 mmHg and 13 ml/sec, respectively. All subjects developed residual urine together with an increase in pulse rate after the administration of the drug. No effect on the systolic blood pressure was noted.
No takes yet. Share an insight, caveat, or question.
Boman et al. (1973) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: