Answers are grounded in this paper and cite their sources.
Shows zero mortality and complete tear closure using the frozen elephant trunk technique for acute complicated Type B aortic dissection, highlighting its utility when endovascular repair is...
OBJECTIVES: Our goal was to report our preliminary results in patients with acute complicated Type B aortic dissection without a suitable landing zone for primary thoracic endovascular aortic repair who were treated with the frozen elephant trunk (FET) technique. METHODS: Within a 25-month period, 14 patients with acute complicated Type B aortic dissection underwent surgical repair using the FET technique. The reasons to perform the FET procedure were an ectatic ascending aorta/arch in 6 patients and the lack of an adequate landing zone in 8 patients. RESULTS: No deaths were observed. A non-disabling stroke occurred in 2 patients. Symptomatic spinal cord injury was not observed. The closure of the primary entry tear was successfully achieved in all patients. In 3 patients, a secondary distal thoracic endovascular aortic repair extension was performed during the same hospital stay. The median follow-up period was 6 ± 5 months. CONCLUSIONS: The FET technique is an attractive method for the repair of acute complicated Type B aortic dissection without a suitable landing zone for primary thoracic endovascular aortic repair. It should be considered as an alternative in patients who are at high risk for retrograde Type A aortic dissection, in patients with an unfavourable anatomy or in patients with connective tissue disease.
No takes yet. Share an insight, caveat, or question.
Kreibich et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: