Key result
Thermodilution and pulsed Doppler ultrasound reliably detected the significant increase in cardiac output induced by cross-clamping of the descending thoracic aorta in pigs.
Why the study?
Are thermodilution and pulsed Doppler ultrasound reliable methods for detecting high cardiac output during cross-clamping of the descending thoracic aorta in pigs compared to transit-time ultrasound flowmetry?
Population
10 pigs anaesthetised with ketamine and fentanyl
Comparison
Cardiac output measurement using pulmonary… vs Transit-time ultrasound flowmetry of the…
Design
Preclinical
Follow-up
30 minutes
Authors
Loading...
Should not yet change aortic surgery monitoring; leaves open translation of porcine validation to humans.
Are thermodilution and pulsed Doppler ultrasound reliable methods for detecting high cardiac output during cross-clamping of the descending thoracic aorta in pigs compared to transit-time ultrasound flowmetry?
p-value: p=<0.05
Thermodilution and pulsed Doppler ultrasound are reliable clinical methods for detecting the significant increase in cardiac output induced by cross-clamping of the descending thoracic aorta.
Aadahl et al. (2000) studied Cross-clamping of the descending thoracic aorta (n=10). Thermodilution and pulsed Doppler ultrasound vs. Transit-time ultrasound flowmetry was evaluated on Cardiac output at 15 minutes following cross-clamping (p=<0.05). Thermodilution and pulsed Doppler ultrasound reliably detected the significant increase in cardiac output induced by cross-clamping of the descending thoracic aorta in pigs.