Answers are grounded in this paper and cite their sources.
Volatile organic compound (VOC)-based fire-risk assessment systems for woodland fires can shorten the time between a fire outbreak and the arrival of fire crews. This can prevent the development of crown fires, which are harder to control than ground fires. Semi-conductor metal-oxide gas sensors possess good technical properties for VOC detection. In this study, the VOC emissions of heated lignocellulose biomass (Eucalyptus globulus) was analysed by gas chromatography–mass spectrometry (GC-MS). Three semi-conductor metal-oxide gas sensors were calibrated to eucalyptol, furfural, α-pinene and 2-methoxyphenol. Among the 20 quantified VOCs, eucalyptol and furfural showed the highest emission rates. The sensors online monitored the temperature-dependent VOC pattern generated by the pre-ignition, at ignition and post-ignition heating stages. The feasibility of such gas sensors for early fire detection is discussed.
No takes yet. Share an insight, caveat, or question.
Paczkowski et al. (2018) studied this question.