Key result
An SVM Classifier with a Trusted Ad-Hoc On Demand Distance Vector routing algorithm demonstrated a sensitivity to diverse noise of 88.4% in 200 samples from the MIT-BIH Arrhythmia dataset.
Why the study?
Intrusion of undesirable noise into biomedical data during fetal heart rate monitoring leads to misinterpretation, requiring effective noise suppression techniques.
A novel SVM classifier and energy-efficient adaptive multiband filtering technique achieved 88.4% sensitivity for noise removal in fetal heart rate monitoring data.
May aid noise-robust monitoring algorithms; hypothesis-generating and should not change practice without validation.
Diagnosis of fetal heart rate is very crucial during the prenatal phase of pregnancy as any delay in the early detection and prevention of anomalies in heart functioning may lead to devastating and life-threatening consequences to the child even after birth. Hence fetal electrocardiogram extraction is to be analyzed using either internal or external monitoring devices. One of the main problems is the intrusion of undesirable noise into the biomedical data, leading to misinterpretation of the diagnosis. Therefore, an effective way to identify and suppress such noise is to be formulated for extracting precise information. Several techniques have been excogitated over 200 samples collected from the dataset of MIT- BIH Arrhythmia, and on cross-validation, SVM Classifier with Trusted Ad – Hoc On Demand Distance Vector routing algorithm has been ascertained to have sensitivity to diverse noise at the rate of 88.4%. Adaptive multiband filtering technique eliminates almost all the noise within the bounded ranges that are already being medically defined. This filter offers high speed yet it occupies more area and glitches when the coefficients are increased by 15. Hence an energy-efficient filter is proposed and results are simulated using MATLAB 2013b, Xilinx ISE 9.1, ModelSim 10.0b, and Cadence Virtuoso under 90 nm technology for synthesis of area, power, and delay reports.
No takes yet. Share an insight, caveat, or question.
Preethi et al. (2019) studied Fetal heart rate monitoring (n=200). SVM Classifier and energy-efficient adaptive multiband filter was evaluated on Sensitivity to diverse noise. An SVM Classifier with a Trusted Ad-Hoc On Demand Distance Vector routing algorithm demonstrated a sensitivity to diverse noise of 88.4% in 200 samples from the MIT-BIH Arrhythmia dataset.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: