This is the authors' abstract. We don't add key points for this paper.
Nested wire array Z-pinch experiments carried out on the MAGPIE generator (1.4 MA, 240 ns) [I. H. Mitchell et al., Rev. Sci. Instrum. 67, 1553 (1996)] are described. In the experiments, a high inductance connection to the inner array was used to suppress the current flowing through it. This allowed the current division expected in experiments on larger generators to be emulated, where the number of wires in the outer array acts to shield the inner array. Initially the suppression of current resulted in the wires of the inner array remaining as small discrete bodies, while the wires of the outer array ablated, prefilling the array with plasma in an identical way to a single array experiment. During implosion the outer array accelerated towards the inner array, snowploughing up the prefilled plasma, producing a rise in x-ray emission. When the outer array traveled past the inner array, a fast inductive transfer of current occurred between them, and the inner array then accelerated towards the axis where it stagnated to produce the main x-ray pulse. The risetime of the main x-ray pulse was significantly shorter than in single array experiments. The dependence of the shape of the x-ray pulse on the configuration of the outer and inner arrays was explored.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Bland et al. (2003) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: