Although arthroscopy of the hip is being carried out increasingly, little is known about the rate of associated complications. We describe a prospective study of 640 consecutive procedures in which a consistent technique was used. The overall complication rate was 1.6%. Complications, none of which was major or long-term, included transient palsy of the sciatic and femoral nerves, perineal injury, bleeding from the portal wounds, trochanteric bursitis and intra-articular breakage of the instrument. We believe that it is possible to undertake this operation safely using the technique described.
No takes yet. Share an insight, caveat, or question.
Griffin et al. (1999) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: