Answers are grounded in this paper and cite their sources.
Non-Faradaic (ion electrosorption) and Faradaic (oxidation?reduction) effects in a batch-mode capacitive deionization (CDI) system were investigated, with results showing that both effects were enhanced with an increase in charging voltage (0.5?1.5 V). Significant concentrations of hydrogen peroxide (H2O2) were observed with the generation of H2O2 initiated by cathodic reduction of O2 with subsequent consumption occurring as a result of cathodic reduction of H2O2. A kinetic model of the Faradaic processes was developed and found to satisfactorily describe the variation in the steady-state concentration of H2O2 generated over a range of CDI operating conditions. Significant pH fluctuations were observed at higher charging voltages. While the occurrence of Faradaic reactions may well contribute to pH fluctuations and deterioration of electrode stability and performance, the presence of H2O2 could provide the means of inducing disinfection or trace contaminant degradation provided H2O2 could be effectively activated to more powerful oxidants (by, for example, ultraviolet irradiation).
No takes yet. Share an insight, caveat, or question.
He et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: