A Materials Characterization Center (MCC) has been established by the U.S. Department of Energy at the Pacific Northwest Laboratory (PNL). Five proposed standard leach tests and typical results using the MCC-1 static test are presented. For the borosilicate glass studied (PNL 76-78), fivefold replicate experiments show that errors in elemental leach values are usually less than ±10%. Regular time-dependent leach curves are obtained, and no significant difference is observed between pure water and simulated silicate/bicarbonate groundwater results. Leaching in salt brine is quite different, especially as shown by elemental depth profiles in the solid; these profiles show significant magnesium penetration into the gel layer from the brine solution.
No takes yet. Share an insight, caveat, or question.
Strachan et al. (1982) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: