The concrete-filled cold-formed steel built-up composite (CF-CFS) column is an innovative and versatile solution that may be used as an alternative structural element in construction. One of the main advantages of composite concrete-filled columns is their fire behavior, which has not been assessed for this specific solution (CF-CFS). Moreover, the available design codes for composite structures do not present a straightforward analytical procedure for concrete-filled cold-formed steel built-up columns. The present paper reports an experimental investigation on the fire resistance of four CF-CFS built-up columns. Twelve CF-CFS short columns were tested. The fire test setup, procedure, and results were fully reported and discussed, including the temperature evolution, load-temperature capacities, and load-deformation. A sequential thermal-stress finite element analysis (FEA) model was developed and calibrated against the test results. Experimental results were compared with design predictions according to the EN 1994-1-2 for composite steel-concrete sections, considering the simplified method (Annex H) and the general method. Moreover, the paper discussed the applicability of EN1994-1-2 to predict the fire resistance of the concrete-filled thin-walled CFS built-up composite columns. The results showed that the predictions according to the simplified design method (Annex H) tend to be highly conservative; but, the predictions based on the general method tend to provide slightly unconservative results, still requiring additional adjustments to improve its accuracy.
No takes yet. Share an insight, caveat, or question.
Rahnavard et al. (2021) studied this question.
Synapse has enriched one closely related paper. Consider it for comparative context: