The performance of W̱COBRA/TRAC code in predicting the flooding, the counter-current flow limit, is evaluated in three geometries important to nuclear reactor loss-of-coolant accident evaluation; a vertical pipe, a perforated plate, and a downcomer annulus. These flow limits are computationally evaluated through transient conditions. The flooding in the vertical pipe is compared with the classical Wallis flooding limit. The flooding on the perforated plate is compared with the Northwestern flooding data correlation. The downcomer flooding in 1/15th and 1/5th scale model is compared with the Creare data. Finally, full scale downcomer flooding is compared with the UPTF test data. The prediction capability of the code for the flooding is found to be very good.
No takes yet. Share an insight, caveat, or question.
Takeuchi et al. (1998) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: