Answers are grounded in this paper and cite their sources.
High-frequency (>10 MHz) ultrasound is used in, e.g., small animal imaging or intravascular applications. Currently available ultrasound contrast agents (UCAs) have a suboptimal response for high frequencies. This study therefore investigates the nonlinear propagation effects in a high-frequency ultrasound field (25 MHz) and its use for standard UCA and diagnostic frequencies (1-3 MHz). Nonlinear mixing of two high-frequency carrier waves produces a low-frequency wave, known as the self-demodulation or parametric array effect. Hydrophone experiments showed that the self-demodulated field of a focused 25 MHz transducer (850 kPa source pressure) has an amplitude of 45 kPa at 1.5 MHz in water. Such pressure level is sufficient for UCA excitation. Experimental values are confirmed by numerical simulations using the Khokhlov-Zabolotskaya-Kuznetsov equation on a spatially convergent grid.
No takes yet. Share an insight, caveat, or question.
Vos et al. (2010) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: