Key result
Transthoracic echocardiography showed 100% sensitivity for detecting ventricular septal defect types and 97% correlation for defect size compared to left ventriculography (P=0.001).
Why the study?
Accurate assessment of ventricular septal defect location, size, and distance to the aortic valve is essential for transcatheter device closure, prompting evaluation of the accuracy of transthoracic echocardiography compared to catheter-based approaches.
Does transthoracic echocardiography accurately assess ventricular septal defect size, position, and distance to the aortic valve compared to left ventriculography in patients eligible for device closure?
Cross-Sectional (n=63)
Does transthoracic echocardiography accurately assess ventricular septal defect size, position, and distance to the aortic valve compared to left ventriculography in patients eligible for device closure?
Transthoracic echocardiography is highly accurate and correlates well with left ventriculography for assessing ventricular septal defect characteristics prior to transcatheter closure.
Supports TTE for VSD assessment pre-closure; leaves open prospective validation versus ventriculography.
Accurate evaluation of ventricular septal defects types (locations) and measurement of the size of ventricular septal defects and distance from ventricular septal defects to aortic valve are essential for successful trans catheter device closure. The aim of study to assess in patient with ventricular septal defects the accuracy of transthoracic echocardiography in determining the size, position (type), and the distance from ventricular septal defects to the aortic valve as compared to trans- catheter approaches. Cross sectional study included patients with a diagnosis of ventricular septal defects with specific criteria suitable for treatment with transcatheter device closure. Eligibility was confirmed during this study and subject demographic (age, sex), growth parameters (height, weight, body surface, and body mass index) were extracted. During study period, patients underwent catheterization for device closure. Prior to catheterization two- dimensional echocardiography evaluation of VSD was done then left ventriculography was performed by interventional pediatric cardiologist to accurately determine the ventricular septal defects location (type), size and the distance from ventricular septal defects to the aortic valve. Sixty-three patients with in ventricular septal defects. The sensitivity of transthoracic echocardiography in detection the types ventricular septal defects of compared to catheter- based assessment (left ventriculography) was (100%) for all types of ventricular septal defects. The correlation coefficient sensitivity of assessment of ventricular septal defects size by transthoracic echocardiography compared to catheter-based assessment was (97%) p-value (0.001*). The correlation coefficient sensitivity of distance of ventricular septal defects to the aortic valve measured by transthoracic echocardiography compared to catheter based measurement was (91 %) p-value (0.001*). Conclusion: Transthoracic echocardiography is useful to evaluate VSDs location and useful to assess measurements of ventricular septal defects prior to transcathetered occlusion. Irregularity of ventricular septal defects shape and its changes during cardiac cycles are sub-optimally estimated by trasthoracic echocardiography.
No takes yet. Share an insight, caveat, or question.
A 2022 study conducted a cross-sectional in Ventricular septal defects (n=63). Transthoracic echocardiography vs. Left ventriculography (catheter-based assessment) was evaluated on Accuracy in determining the size, position (type), and distance from ventricular septal defects to the aortic valve (p=0.001). Transthoracic echocardiography showed 100% sensitivity for detecting ventricular septal defect types and 97% correlation for defect size compared to left ventriculography (P=0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: