The ability to confidently measure the concentration of dissolved oxygen (D.O.) in ground water is a key aspect of remedy selection and assessment. Presented here is a comparison of the commonly practiced methods for determining D.O. concentrations in ground water, including colorimetric, membrane‐covered electrode, and modified Winkler techniques. The Winkler titration (azide and permanganate modifications) is the most accurate and precise technique for determining D.O. and is appropriate for applications with stringent data quality objectives. In addition, excellent correlation over a wide range of D.O. concentrations was found between Winkler titrations and colorimetric tests using the rhodazine D (below 1 part per million [ppm]) and indigo carmine reagents (above 1 ppm). Electrode measurements represent the simplest method for determining D.O. concentrations on a continuous basis and electrode determinations positively correlate with Winkler results above 1 ppm. Below 1 ppm, electrodes provide only a qualitative measure of low D.O. level, apparently due to slow electrode response.
No takes yet. Share an insight, caveat, or question.
Wilkin et al. (2001) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: